Shrinktek Polymers International - heat shrink products  
enquire about heat shrink products
browse products search for heat shrink products
Home >>> Product Details Heat Shrink convertion calculator
 

SK
175°C High Temperature Flame Retarded Chemical Resistant PVDF Heat Shrinkable Tubing
minus
Shrink Ratio:2:1
Operating Temperature:-55°C to 175°C
Shrink Temperature:170°C
Resistance:Outstanding resistance to abrasion, chemicals and solvents
Applications:Suitable for harsh environmental applications
pdf iconDownload data sheet

enlarge
Usage
AviationDomesticElectricalMilitaryTransport
ComputingIndustrialAutomotive
*Roll over icons for description
Standard Colours
CLEARCLEAR
Other colours not presently available
Standard Packaging On reels and 1.2m (4ft) lengths
RoHS Compliance
2003/11/EC Compliant?
2002/95/ECFrom What Date?
YesYes>3 Years
minus add to my enquiries
Item
SK:175°C High Temperature Flame Retarded Chemical Resistant PVDF Heat Shrinkable Tubing

Colour  
Size  
Quantity   
       

Heat Shrinkable Products
Quality Assured | Rapid Delivery | Bespoke Cutting/Marking

 

Shrinktek is a specialised supplier
of heat shrinkable products
To place an order by phone, call or email us
UK +44 (0) 1452 714900 | USA +1 (973) 364 9990 | Canada +1 (604) 858-7131
Hours: Mon-Thu 8:30am-5.00pm, Fri 8:30am-1.30pm GMT/EST

Copyright © 2001 - 2006 Shrinktek Polymers International Ltd. Website and hosting by Webnetism

Property

Test Method

Values

Tensile Strength IEC 60684-2 Clause 19.1 and 19.2 35 Mpa (min)
Ultimate Elongation IEC 60684-2 Clause 19.1 and 19.2 150% (min)
Heat Shock IEC 60684-2 Clause 6 (4hrs at 300°C) no dripping, cracking or flowing of outer wall
Heat Ageing IEC 60684-2 Clause 39 (168hrs at 200°C)
Heat Ageing (Tensile Strength) Clause 19.1 and 19.2 15 Mpa (min)
Heat Ageing (Ultimate Elongation) Clause 19.1 and 19.2 75% (min)
Corrosion (Copper Mirror) IEC 60684-2 Clause 33 no corrosion
Electric Strength
32KVolts/mm
Resistance to Selected Fluids IEC 60684-2 Clause 36 excellent (for list of fluids and test temperatures se ST 6009)
Resistance to Selected Fluids (Tensile Strength) Clause 19.1 and 19.2 25 MPa (min)
Resistance to Selected Fluids (Ultimate Elongation)
150% (min)
Fungus Resistance ISO 846 Method B
Fluid Resistance (Tensile Strength) IEC 60684 - 2 Clause 19.1 and 19.2 35 Mpa (min)
Fluid Resistance (Ultimate Elongation)
150% (min)
Ordering
Size
Min Expanded
Diameter
Max Recovered
Diameter
Nom Recovered
Wall
Standard
Lengths
Standard Reel
Length

ins

mm

ins

mm

ins

mm

ins

mm

m

ft

m

ft

3/64

1.2

0.046

1.2

0.023

0.6

0.010

0.25

1.2

4

300

1000

1/16

1.6

0.063

1.6

0.031

0.8

0.010

0.25

1.2

4

300

1000

3/32

2.4

0.093

2.4

0.046

1.2

0.010

0.25

1.2

4

150

500

1/8

3.2

0.125

3.2

0.062

1.6

0.010

0.25

1.2

4

150

500

3/16

4.8

0.187

4.8

0.093

2.4

0.010

0.25

1.2

4

150

500

1/4

6.4

0.250

6.4

0.125

3.2

0.012

0.30

1.2

4

75

250

3/8

9.5

0.375

9.5

0.187

4.8

0.012

0.30

1.2

4

75

250

1/2

12.7

0.500

12.7

0.250

6.4

0.012

0.30

1.2

4

75

250

3/4

19.0

0.750

19.0

0.375

9.5

0.017

0.43

1.2

4

60

200

1

25.4

1.000

25.4

0.500

12.7

0.019

0.48

1.2

4

60

200

Type Shrinktek

Military

Underwriters Lab

CSA

SK ST6009
AMS-DTL 23053/8, DEF STAN 59-97,
VG 95343 Pt5
UL 224 VW1, 600V, 125°C
FILE NO. E196685
LR 31929, 600V, 125°C (OFT)
FILE NO. LR228795